Modules with EtherCAT interface for the acquisition/generation of peripheral signals.
Common Data:
EtherCAT ports: 2
Power supply: 24V±30%
Housing: Italtronic 120 x 101 x 22,5 mm
Protection Class: IP20
Mounting: DIN rail assembly

| | EC-CNT4 | | Counter Module 4 channels ABZ, max. 2MHz per track Counter or frequency or period duration measurement Ultrahigh precision Quadrature (simple/double/quadruple evaluation) or A forward + B backward or pulse + direction Transducer inputs are galvanic isolated from logic circuit | |
| |
| | | | | | | |

| | EC-AIN8
EC-AIN8A | | Analog Input Module 8 channels Resolution: 13 (EC-AIN8) or 16bit (EC-AIN8A) Fast conversion time: 25us Input: ±10V, ±5V, ±2.5V, 0..10V (programmable, 13bit model only)
Input: ±10V (16bit model only) Analog inputs are galvanic isolated from logic circuit | |
| |
| | | | | | | |

| | EC-AOUT8 | | Analog Output Module 8 channels Resolution: 12 (14/16)bit Fast conversion time: 30us Output: 0..5V, 0..10V, ±5V, ±10V (programmable) Analog outputs are galvanic isolated from logic circuit | |
| |
| | | | | | | |

| | EC-SSI2 | | SSI Module Acquisition of absolute position transducer signals 2 channels Programmable data word length 1..32bit 62.5/125/250/500kHz, 1MHz SSI clock driver is internally powered SSI interfaces are galvanic isolated from logic circuit | |
| |
| | | | | | | |

| | EC-BIN32 | | Binary Input Module 32 channels 24V inputs, 2mA constant current Input filter for noise suppression Binary inputs are galvanic isolated from logic circuit | | | |
| | | | | | | |

| | EC-BOUT32 | | Binary Output Module 32 channels 24V outputs, min. 0.5A per channel Reverse polarity protection Overtemperature and shorted load protection Binary inputs are galvanic isolated from logic circuit | | | |